Mark 93 Series
Sanitary Steam Traps
STERIFLOW
TM
by Jordan Valve
3170 Wasson Road • Cincinnati, Ohio 45209
Telephone 513.533.5600 • Fax 513.871.0105
Toll-Free Telephone: 800.543.7311
steri[email protected] • www.steriowvalve.com
The Mark 93 is a balanced port, thermostatic steam
trap designed specifically for use in validated clean
steam systems. The sanitary design follows ASME BPE
guidelines including a 20Ra µin internal nish, self-
draining design, and all relevant materials, marking
and documentation guidelines.
The MK93 has been specifically designed to provide
higher flow rates at low pressures and low subcooling
levels. In lab testing, the MK93 consistently exhib-
ited excellent flow rates at subcooling levels of less
than 3°F or less (<1,7°C). Note: Low subcooling op-
eration insures that condensate won’t back up and wet
(cool) the upstream validated temperature sensor.
There are two base designs within the MK93 product
range: the standard MK93 – good for inlet pressures
(P1) up to 50 psi (3,4 bar), and the MK93 Option “P”
for inlet pressures ranging from 45 – 90 psi (3,1 – 6,2
bar). Both designs are rated to 90 psi (6,2 bar) operat-
ing pressure but are recommended for use within the
specified inlet pressure ratings.
During start-up, the bellows element is contracted and
fully open to discharge all non-condensable gas and
condensate. The heat of entering steam causes the
element to expand, closing the valve. As condensate
accumulates in the body, the element cools, causing the
bellows/stem tip to retract allowing condensate to drain.
Features
Low subcooling operation reduces probability
of temperature validation faults and resultant SIP
delays
CRN Registration Number available
Thermostatic steam trap in 316L stainless steel that
is designed for clean steam tracing, drip-leg and
process applications
All 316L stainless steel housing and internals
Polished components – body interior and exterior
are mechanically polished to 20Ra finish
Sanitary clamp ends standard, other ends (tube
weld, threaded, ISO/DIN) available upon request
Self draining when installed vertically (outlet side
down)
New design provides excellent flow rates with low
subcooling
FDA and USP Class VI TFE-VIT gasket stan-
dard on clamped body, or FDA and USP
Class o-ring on bolted option
Option for electropolished body
Warranties:
5 year material and workmanship
2 year low subcooling performance
Applications
Typical applications are: sterilization drain-
age for fermenters, bioreactors, separa-
tion and filtration equipment, lyophilizers,
autoclaves, process piping equipment and
steam barriers
Condensate drainage from process sys-
tems using clean steam – fermenters,
bioreactors, SIP systems and sterilizers
Sanitary Valves Mark 93 Sanitary Steam Traps
NEW! Horizontal
connections
available
Page view 0
1 2 3 4 5 6 7 8 9

Summary of Contents

Page 1 - Mark 93 Series

Mark 93 SeriesSanitary Steam TrapsSTERIFLOWTM by Jordan Valve3170 Wasson Road • Cincinnati, Ohio 45209Telephone 513.533.5600 • Fax 513.871.0105Toll-Fr

Page 2 - MK93 Sanitary SteaM trapS

MK93 Sanitary SteaM trapSFeatures & BeneFits – MK93 with tri-ClaMp endsFDA, USP Class VI Gasket standardEasy service body Tri-ClampTMHigh flow ra

Page 3 - Flow CapaCity taBle

MK93 Sanitary SteaM trapSspeCiFiCationsSizes: • 1/2”, 3/4", 1" • DIN DN15, DIN DN20, DIN DN25• ISO DN15, ISO DN20, ISO DN25End Connection

Page 4

MK93 Sanitary SteaM trapSdiMensions - VertiCal ConneCtionsBolted Body (93B) (1/2”, 3/4”, DN15, DN20) Welded Joint (93W) (1/2”, 3/4”, DN15, DN20)2.50

Page 5

MK93 Sanitary SteaM trapSdiMensionsMK93C 1/2", DN15 Horizontal Inlet/Outlet (CHCH, MHMH, PHPH)4.53 (115,2)2.00 (50,8)3.62 (92)Section A-AA A -5-

Page 6

MK93 Sanitary SteaM trapSdiMensions - horizontal ConneCtionsMK93C 3/4", DN20 Horizontal Inlet/Outlet (CHCH, MHMH, PHPH)Section A-AA A3.84 (97,5)2

Page 7

diMensions - horizontal ConneCtionsMK93C 1/2", DN15 Vertical Inlet/Horizontal Outlet (CVCH, MVMH, PVPH)MK93 Sanitary SteaM trapSSection A-AA A2.0

Page 8

diMensions - horizontal ConneCtionsMK93C 3/4", DN20 Horizontal Inlet/Vertical Outlet (CVCH, MVMH, PVPH)MK93 Sanitary SteaM trapS2.00 (50,8)Sectio

Page 9

Steriflow Valve reserves the right to make revisions to its products, specifications, literature, and related information without notice. Please visit o

Comments to this Manuals

No comments